Wood-frame house or timber-frame ?
[From Wikipedia, Mar 2012]
Caution: Paragraphs herein mention the low toxicity of poisons used in preserving timber these days, but older houses used lethal poisons, and today's insulation, should the house catch fire, rapidly produce clouds of poisons which choke the occupants, thus preventing escape.
People are not trapped by fire but by poisonous clouds produced by fire. Modern houses are traps. Newspapers relate stories of children screaming for help while the parents were unable to enter. Every room should have two means of escape - by door and by window. Could young children, yours or visitors, escape from bedrooms in your house ?
Wood frame or timber-frame ?
The wood-frame house uses thinner lighter timbers much closer together, braced by metal straps, with studs prevented from movement and bowing by noggins, and by nailed butt joints. Long gone are the days when we mortise-n-tenoned the studs to the wall plate. Even the nails are short and thin, for injecting into cheap softwoods by hand-held 'gun'. A mere two persons can erect a wood-frame house.
The Wood-framing
The timber-frame house uses massive wooden components joined in a cathedral-like framework that requires no interior load-bearing walls. Girts, plates and purlins tie the posts and rafters together, while diagonal knee braces add rigidity. Factory-built structural insulated panels (SIPs) are roof, walls, insulation and window framing all in one. (See Timber-frame for diagrams and photos.)
I have not seen such a timber-framed house in Australia, although we call our wood-framed houses "timber-framed"; and we have never organised the manpower capable of erecting a genuine timber-frame. Some films of the US Western Plains show their construction using large teams of settlers lifting the massive timbers into place. The US once enjoyed large tracts of huge straight trees from pristine conifer forests, but Australian forests rarely yield such timbers, and, when they do, those timbers are much heavier.
The Timber-framing
House frame
A wood frame is a skeleton of timber components which is then clad outside and usually lined inside as well.
To this skeleton is added roofing, exterior wall claddings, flooring, windows and doors, internal linings.
(In Australia, up into the early 20th century, sometimes poverty prevented lining the inside. Sometimes they glued newspapers to the inside of the exterior cladding to keep out the drafts. (Life was a battle; poverty was forever.) Others lined the inside with wood boards instead of cladding the outside, but these invariably had deep verandahs for weather protection.)
Construction process
Typical lightweight timber construction consists of framed and braced structures with claddings (corrugated steel on the roof, plasterboard or slats coated with a mix of horse-hair and lime-based plaster, inside; weatherboards or brick wall or cement sheets on the outside). The type of framing can range from large, widely spaced timbers to the closely spaced light timbers commonly seen in stud frame construction. The process of construction may begin with a concrete slab onto which continuous frames are fixed, or the placement of piers or pad footings to carry posts or bearers.
Timber components may be fabricated off or on-site. Modern construction techniques in Australia generally favour off-site fabrication of items like trusses with the extent of on-site fabrication of elements like stud frames being dependent on individual designs.
A sub structure of piers, piles, stumps, posts, dwarf brick walls or perimeter masonry walls support the building frame.
The sub structure carries the load to the footings, which depending on local practice may be sole plates of durable or treated timber or commonly, a concrete pad or a rectangular section reinforced concrete-filled trench.
The use of piers and posts can greatly reduce the need for cut-and-fill on sloping blocks.
Structural capability
Timber has good compressive strength but is strongest in tension. Structural design techniques exploit this characteristic that can be clearly seen in the design of roof trusses.
As well as solid timber there are many products that are composites or made of components that can be used in lightweight construction. These include plywood, particle board, fibreboard and engineered products such as Laminated Veneer Lumber (LVL) and glue laminated timber (Glulam). When using composite timber internally, avoid those with glues that release poisons into the air.
There is a timber product to meet most structural requirements, and engineered timber products can be manufactured to meet specified structural requirements.
Thermal mass
In general timber has low thermal mass. There are hardwoods that have similar densities to concrete but these are not common building materials. Thermal mass can be built into lightweight timber constructions, if a particular design requires it, by using elements such as:
- concrete slabs
- masonry features
- water tanks integrated into walls or floors.
Insulation
Timber is a natural insulator due to air pockets within its cellular structure. Most timbers are extremely low thermal conductors relative to other building materials. The conductivity of aluminium is typically about 1700 times as great, steel 400, concrete 10, brick and glass 6 times; but bulk insulation materials, such as mineral wool, may have as little as a third of the conductivity of wood.
As most timber buildings in Australia are stick built stud construction, the spaces between noggings and joists can accept bulk insulation readily. Lightweight timber constructions can be designed to incorporate as much or as little insulation as the construction requires. Reflective materials can also be readily incorporated into lightweight timber constructions.
The low thermal conductivity of timber minimises the occurrence of thermal bridging that can reduce the overall R-value of a structure.
Sound insulation
The sound insulation of walls is usually obtained by providing a barrier of sufficient mass to absorb the sound energy. In lightweight timber constructions the wall cavities provide a cushion of air that absorbs some of the sound energy, and as long as here are no rigid bridgings to transmit the energy this can be a reasonably effective barrier. Acoustic barriers can be supplemented by placing insulation materials in the wall cavity and this also helps to reduce the drumming effect of large sheets of lining material.
Vermin resistance
Termites are a main concern for lightweight timber constructions. The two main methods of dealing with the threat of termites are chemical and physical. Current building regulations emphasise managing termites through physical barrier systems and inspections rather than the environmentally harmful methods of the past.
Physical barriers prevent hidden entry. They are inspection systems rather than prevention systems. Termites attack from underground and the best risk management strategy is to design the house for easy inspection, ie. leave an accessible space to inspect for termite activity.
Lightweight timber constructions, especially those with elevated floors or pole framing, lend themselves to easy inspection for termite activity.
Other vermin such as mice can be controlled by ensuring that all cavities are sealed.
Durability and moisture resistance
Timber is an organic material and deteriorates due to weathering. The main way of preventing weathering is protection of the timber surface. This may be achieved by appropriate design detailing, so that the timber remains dry or sheds water quickly. It may be achieved by treatment with an appropriate surface coating of oil, varnish or paint. Such coatings on external timber components of buildings generally need replacing every 5-7 years.
Weathering can be reduced by the selection of durable timber species in the first instance. Over a forty year life a fully maintained timber clad building will require less embodied energy than common alternatives, see table below.
A lightweight timber construction can have a very long life, making the dwelling more valuable both from an economic and environmental perspective. This can be achieved using appropriate design, building practices and detailing.Durability and moisture resistance
A lightweight timber construction can have a very long life, making the dwelling more valuable both from an economic and environmental perspective. This can be achieved using appropriate design, building practices and detailing.
Toxicity and breathability
Untreated timber is generally non-toxic. Camphor laurel is an exception. Provided timber is not sealed with material that is impervious to air it maintains its breathability. The durability of the timbers used in the lightweight construction can be improved by treatments. Very low VOC treatments are readily available nowadays and most are water rather than solvent based.
Wood frame construction
A typical modern wood-frame house consists of:
- reinforced concrete strip-footing
foundation upon which a platform is constructed of joists covered with plywood or
oriented strand board (OSB) to form the ground-floor level of the house (also known as
platform wood-frame construction). This platform is connected directly to the foundation
with anchor bolts. On this base, the exterior and interior walls are erected.
- walls
consist of a horizontal sill plate with vertical timber studs with board or panel sheathing
nailed to the studs on the outside of the building (Figure 4). After the first-story walls are
completed, the second-story floor is constructed, which, in turn, acts as a platform for
erection of the second-story walls. This process is continued for all the stories.
- roof
of prefabricated trusses, covered with sheathing
and roof tiles
- standardized components a wide range of
compatible fittings, such as doors, windows, electrical and plumbing
fixtures, and the like, which are designed to be easily installed in the wood structure.
- insulation within the hollow wood-frame wallsto satisfy any climatic conditions.
- plumbing, heating, and
electrical services easily installed within the walls, in the open spaces above ceilings,
within the floor structure, and in the space between the first (ground) floor and the
ground below.
Wood-frame houses can be up to three stories in height, if allowed by typical
code limits.
The vast majority of residences in the USA, Japan, and Canada are wood-frame
construction, as described above. Canadian one-story residences are often nonengineered
constructions, which differ from the USA, Japan, and the Russian Federation’s
government housing, where residences are engineered by an architect.
Use & cost
Today, wood frame is used for approximately 90% of the houses constructed in the USA,
predominantly in suburban regions. Costs vary greatly by region and house design, and
range from about 650 US$/m2 to 2200 US$/m2 (WHE Report 90, USA), excluding land cost.
The cost for a single-family residential house in Japan ranges from 1100 US$/m2 to 2800
US$/m2 (WHE Report 86, Japan).
Structural system
In the typical wood frame house, gravity loads are accommodated by wood “studs,” 75 x 62mm,
commonly placed at 400mm/16" centers. Floor and roof-framing
members are commonly 50mm/2" in thickness and may be 150-350 mm/6-14" in depth. Lateral resistance is provided by either a bracing by diagonal metal strips, or a shear-wall system
consisting of plywood or manufactured wood panels (particle board) nailed to vertical
studs, creating shear walls.
Like all building, wood frame construction is highly
codified and regulated. See the Australian Building Code which covers the whole of the continent, stretching 3300km from the sub-polar gales of the south, across snow-covered alps and burning deserts, to the hot monsoonal cyclones of the north. A job well done. Similar manuals are available in other countries.
Japanese wooden housing is built using “post-and-beam” construction, similar to the construction in the USA and Canada. Wooden posts, with
cross-sectional dimensions 105-150 mm, carry gravity loads.
Theroof structure is made out of wood and is covered by roof tile or slate. The roof load is
transferred to the wood frame. The roof-supporting system in Japan is different from that
of western countries and is based only on vertical and horizontal members. No diagonal
members or trusses are used, as is common for similar construction in Western countries.
For most timber structures in Japan, Canada, and the USA, the lateral load resistance is
provided by wooden shear walls with plywood or manufactured wood panels (“particle
board”) nailed to the vertical wooden members. The building code generally regulates
the number and dimensions of shear walls. In Japan another common
approach to shear-wall construction is a wooden wall with interior diagonal brace members. However, the traditional Japanese house did not have a diagonal
brace. A thin lumber running through posts, called “Nageshi,” and a thick wood post
provided lateral resistance. Japanese construction also often uses metal joints, and in
recent wooden housing, plates are used to stiffen the wood frame.
While Australia's wood-frame housing is moving to plywood shear walls, it mostly uses diagonal bracing with metal strips. Mortice-&-tenon joints disappeared before 1950. Nails across butt joints have been replaced by toothed metal plates hammered in place.
Alternate approaches to the post-and-beam construction are the Russian Federation’s
timber panel construction and horizontal timber log construction. The panel buildings use load-bearing panel walls to carry
gravity loads. The layered paneling acts as a shear wall to resist lateral loads. These
layered timber panels also serve as floor and roof diaphragms. The horizontal timber
system uses stacked logs as vertical and lateral load-resisting elements.
The horizontal logs are joined by hand-sawn connections without mechanical fasteners.
Seismic performance
The seismic resistance of wood-frame structures is relatively high, provided the quality
of materials and the construction are satisfactory. The buildings generally tend to
be lightweight, especially when compared to brick or stone, which helps reduce
earthquake forces on the structures. In addition, because of the relatively large number
of walls and the use of numerous nailed connections, wood-frame houses have
traditionally performed well in earthquakes so that deaths and serious injuries are rare.
The seismic performance of wood-frame construction is greatly enhanced by its
non-structural components (WHE Report 82, Canada). The architectural finishes and
numerous non-load-bearing walls increase the amount of energy the building can
dissipate during an earthquake because these additional systems absorb energy as they
are damaged. Finishes, such as stucco that are used in the USA, Canada, and Japan,
crack and spall, which adds additional earthquake resistance to buildings; therefore, a typical wood frame house is usually considered to have medium-to-low vulnerability to
earthquakes.
Typical seismic-strengthening techniques
- Cripple wall bracing: simple, very low cost when done by a homeowner who has moderate carpentry skills. A cripple wall is a low stud wall sometimes used between the top of the
foundation and the underside of the first floor. The collapse of a cripple wall or damage
to it from an earthquake are generally not life-threatening but expensive to repair. It is not necessary to brace the entire wall as long as all corners are braced and some
intermediate portions of wall are also braced, depending on the length of the walls
- Basic anchoring: and connection of the wood building to the foundation is essential.
- Heavy tile roofs: often lead to the collapse of buildings as
seen in the 1995 Kobe earthquake; can be changed to lighter weight
materials.
- Better carpentry: Older buildings with studs are joined by finger joints without any mechanical fasteners, are prone to seismic damage.
- Anchoring: During a seismic event, buildings that are not properly bolted to their
foundation may move off the foundation, causing structural damage and possible
severance of water, gas or electrical lines. This is a
major seismic deficiency.