Corrugated steel
This article, apart from my insertion of advantages and disadvantages, comes from an advertisement. Having roofing experience, I agree with the information selected here. No benefit accrues to PT from this chapter.
[Fasteners or screws have their diameter given as a gauge, denoted by #, as in #12 and #10.]
Advantages
- Cost saving:
- uses very little steel for the area covered
- relatively cheap compared to heavy tiles
- lightweight, easier and quicker to handle (amazingly fast to cover a huge gable roof); reducing labor costs
- quick and easy to cut to shape; quick to attach to the house frame (with self-tapping screws, without pre-drilling as with dry weatherboards)
- lightweight, so can use a lighter supporting frame, with cost saving
- quick to clad walls externally and the roof, with big saving in labor costs.
- if it is not windy, even huge sheets of steel can be easily lifted by hand or rope to the roof; packs of corrugated steel can be lifted by crane onto the roof frame.
- Walls no longer need painting, reducing maintenance and inconvenience
- does not suffer from dry or wet rot, or termites
- easily removed and replaced after storm damage
- less prone to storm damage than tiles
- lasts for more than 30 years; easy to replace
- flexible, bending both ways
- attractive colors
- the corrugations can be used for visual effect:
- run horizontally to make the building look longer or lower, or to fit into the horizontal strata lines of sandstone hills in the background
- run vertically to emphasize the height and slimness a tall house, or reduce the appearance of length
(just like a striped dress or suit can make a person look taller and slimmer, or shorter and stockier.) This visual effect of corrugations might be seen as a disadvantage.
Disadvantages
- steel is a good conductor of heat, stealing away your winter warmth and broiling you in a hot summer. Internal insulation is a must.
- roof is slippery after literally a few drops of rain or light dew
- roof kinks easily when walked on
- internal moisture from the rooms below, as the night cools, condenses inside on the cold steel
- does not let the air flow in and out, like some tiles do.
- for a house with steel external walls, the re-sale value will probably be less that of a similar brick-clad house
- 'talks' 24 hours each day, with expansion and contraction induced by changing temperature.
Roofing & Walling
Corrugated steel gives you the versatility of a traditional corrugated roof or wall cladding profile with the strength and light weight of a modern steel building product.
Corrugated steel is roll-formed and is available in a wide range of colors. Corrugated steel is a cheaper cladding for many building applications.
Installation
The sheets of Corrugated steel overlap each other and are fixed progressively along the building in the opposite direction to the prevailing weather. This gives complete weather protection and a fast and efficient method of installing the roof.
Each sheet includes an “under” rib and “over” rib to form an anti-capillary drain which prevents water entry at side laps.
Preparation
Packs of corrugated steel can be lifted onto the roof frame so that all sheets are the right way up and with the over edge facing the end of the roof where laying will commence.
Prevent roof damage by walking on at least two ribs to distribute the weight over the foot and walk across the roof over the supports (battens).
When the roof pitch is less than 250 or where there are extreme weather conditions, turn the sheet ends up about 800 at the high end and down about 150 at the gutter or low end. A shifting spanner can be used to do this.
End lapping
When two or more sheets are required for full length cover, start laying at the gutter and work up to the ridge and then start the next run at the gutter again.
The minimum end laps required are:
- Roofs:
- Pitch up to 150 – 230mm
- Pitch over 150 – 150mm
- Walls: 100mm
End laps:
- in roofs with a pitch of < 50 (1 in 12) end laps must be sealed.
- End laps require:
- positioning over a support
- support spacings either side as recommended for an end span.
Recommended fasteners
Steel Framing (up to 5mm):
- Crest Fixed – #12 x 35mm Hex Head Self Drilling Tek with Neo. Washer.
- Valley Fixed – #10 x 16mm Hex Head Self Drilling Tek with Neo. Washer.
Timber Framing:
- Crest Fixed – #12 x 50mm Hex Head Type 17 Self Drilling Wood Screw with Neo. Washer.
- Valley Fixed – #12 x 25mm Hex Head Type 17 Self Drilling Wood Screw with Neo. Washer.
Side lap fasterners
These are added to give weatherproofing at the midspans of the sheets for support spacings over 900mm for roofs and 1200mm for walls. Use #8 x 12mm Hex Head Type 5 Self Drilling Screw with Neo. Washer or blind rivets.
Method of fixing
Roofs – Screw through the crests only, using 3 fasteners/sheet or 5 Fasteners/sheet depending on the location. At the end sheets 5 Fasteners/sheet must be used. (For steep gable roofs, because of the lifting action of gale-force winds, I would use 5 fasteners throughout.)
Walls – Screw through crests or valleys. 3 Fasteners/sheet or 5 Fasteners/sheet can be used depending on location. At the ends of sheets 5 Fasteners/sheet must be used. If valley fastening is used, side lap fasteners must be added beside each main fastener.
Precautions
Always use a spreader bar and fabric slings to prevent damage when unloading bundles of sheeting with a crane. When manually handling sheets use clean dry gloves and do not drag sheets over each other or use disk grinders within reach of sprayed metal dust. Storage of sheets should be above ground and under cover.
Crest fasteners must not be overtightened but driven in until slight deformation of the rib is observed and the neoprene waster is fully sealed.
Do not locate fasteners less than 25mm from the end of sheets. Do not use punches to form holes for fasteners. Holes must be drilled or self drilling fasteners used.
Coverage
Corrugated steel has an effective coverage of 762mm when laps of 1.5 ribs are used.
Roof pitch
Corrugated steel is designed so that sheets overlap by a minimum of 1.5 ribs, which prevents the entry of water. The minimum recommended roof pitch is 50.
Non-cyclonic