The steel found in many concrete structures is called reinforcement. Reinforcement helps:
resist tensile forces
resist shear forces
control cracking.
Concrete properties
Strength
Normal concrete
Reinforced concrete
Compressive Tensile Shear
High Very low Very low
Very high Very high Very high
Why reinforcement ?
As a force is applied to concrete there will be
compressive, tensile and shear forces acting
on the concrete. Concrete naturally resists
compression (squashing) very well, but is
relatively weak in tension (stretching).
Horizontal and/or vertical reinforcement is
used in all types of concrete structures where
tensile or shear forces may crack or break
the concrete.
Horizontal reinforcement
helps resist tension forces.
Vertical reinforcement helps resist shear forces.
Below are some examples of using reinforcement:
In a suspended (off-the-ground) concrete slab,
horizontal reinforcement resists tension, while vertical
reinforcement (in say supporting beams) resists
shear forces.
In a slab-on-ground, reinforcement increases
the tensile strength and helps control the width of
shrinkage cracks.
(See Cracks.)
It does not prevent cracks but controls the width that cracks can open.
Uses of reinforcement include:
Increasing the spacing of control joints
Odd shaped slabs
Slabs with re-entrant corners.
The major points are:
Reinforcement position: Horizontal position: The position of reinforcement will be shown in the plans. Reinforcement must be fixed in
the right position to best resist compressive, tensile and shear forces and help control
cracking.
Vertical position: The reinforcement in trenches and slabs rests on
bar chairs and must be securely fixed to the
bar chairs so it cannot move when concrete is
placed around it.
Concrete cover: The reinforcement must be placed so there is enough concrete covering
it to protect it from rusting. To ensure durability, both the concrete cover and
strength should be shown in the plans.
Cracking and reinforcement: Reinforcement alone will not stop cracking, but helps
control cracking. It is used to control the width of shrinkage cracks. (See Cracks.)
Concrete reinforcement bond: To help control the width of cracks, or their location (at
joints), there must be a strong bond between concrete and reinforcement. This allows the
tensile forces (which concrete has a very low ability to resist) to be transferred to the
reinforcement.
To help achieve a strong bond:
The reinforcement should be clean (free from flakey rust, dirt or grease).
The concrete should be fully compacted around the reinforcement bars.
Reinforcing bars and mesh should be located so that there is enough room between
the bars to place and compact the concrete.
To improve the transfer of tensile forces to the steel,
the reinforcement is often anchored by:
bending
hooking
lapping the bars.
Types of Reinforcement:
Mesh sheets: mesh may
be made from either smooth or deformed bars.
Typical mesh sizes are SL42, 52, 62, 72 and 82.
The
SL stands for S = Square Mesh, L = Low Ductility.
As for the
numbers, in SL42 the 4 is the nominal bar size (diameter) and the 2
refers to the wire spacing (200 mm).
Loose bars: Loose bars are normally deformed.
Typical bar diameters are 12, 16, 20 and 24 mm.
Reinforcement materials:
Synthetic fibres:
aid in minimising early-age plastic shrinkage
reduce the presence of excessive bleedwater.
In slab on ground
construction the control joint spacing is the same as plain concrete.
are not a replacement for fabric or steel reinforcement.
Steel fibres:
used for the above
improve the toughness of concrete
used to control drying shrinkage cracking over limited spacings and for odd-shaped
slabs.
increase the flexural, or bending, strength of concrete.