Fencing 2
Electric fencing
Better called 'powered wire fencing', this is useful for both internal and boundary fencing. It can also be used as a temporary fence after floods, fire and stock damage, since the power supply, a simple 6v20A (6 volt, 20 ampere) rechargeable battery operating the controller lasts about 3 weeks in continuous use and takes only 24 hours to recharge; perhaps have one extra battery for rotating around all your electric fences, during recharging. The wire can be lifted or lowered to let stock through, or raised on 2 posts to permit a gate to operate; or quick release spring hooks with insulated handles can give temporary passage.
Often only a single wire is needed to contain one type of stock:
- adult cattle: single strand wire 750mm above ground
- sows: single wire 375mm above ground
- gilts: 300mm above ground
- piglets:a second wire 250mm from ground is also necessary
- sheep: 2 wires about 375 and 825mm above ground provide the most satisfactory spacing. The wires must be kept taut so that when the sheep rushes the fence, the wire passes through the hair to the skin.
Electrified wire is more generally used owing to its low cost and the simplicity and ease of moving. A 6V20A (6 volt, 20 ampere) battery Two such batteries, with one being recharged while the other is in use, enables a continuous use at low maintenance cost.
When a wire is near the ground, vegetation has to be cut frequently (or cropped by sheep) if short-circuiting is to be avoided. One UK source states, "To save cutting, creosote poured from a watering can below the wire kills off growth". If you do that in Australia, the Dept of Primary Industry will probably have you prosecuted for poisoning the ground; so beware. The soil is ours only temporarily; we pass it on to our children and so need to look after it, not poison it.
Rats can often be cleared overnight from an old barn by running 2 wires, one earthed and one alive, along the rafters at wall plate level, the wires being 50mm apart.
Where diary cattle are pastured intensively, one wire forming a rectangle can contain the herd and be moved further across the paddock whenever the current area has been fully grazed.
If the top wire of a fence is insulated from the ground, it can be used for powered wire fencing without recourse to another wire. If all wires are insulated, alternate wires can be positively/negatively charged, forming a formidable barrier to all stock, wildlife and vermin, regardless of size: rabbits, foxes, kangaroos, emus, cattle.
The dog fence of 6-7 powered wires 1.2-1.4m high has contained wild dogs in many large areas of Australia.
The most formidable fence is the Burston sloping fence using 10/11/12 wires on a 450 slope, 1.65-1.8m high, in positive-negative pairs to about 60% of slope length. In addition a smooth firm surface to avoid shorting of power, coupled with crucial spacing of the bottom wire to ground, are considered essential.
Points to note:
- Powered lines alongside roads require local authority approval, even if they are inside the boundary fence.
- For the gauge/strength of wire, take into account:
- wind
- perched birds (whole flocks of starlings)
- suspended ice
- robustness of insulators (UV degradable ?)
- means of adjusting clearance height with mechanical tensioners on the pole guys
- Rail codes for the crossing of tracks under the ballast.
However, often the solution is merely 'Use a second battery'.
Advantages of electric fencing
Advantages:
- Low wire tensions are cheaper along contours, over rocky outcrops and large stones, around severe erosion, in sand ridge and stoney rise country, and across ground subject to flooding or waterlogging.
- Low cost and easy to erect for salinity control, revegetation and agroforestry programs.
- Low cost and quick upgrading or repairs to failed netted or fabricated fences or conventional fences damaged by floods.
- Easy elimination of internal gateways using a range of low cost devices to elevate or push down the wires and allow movement of stock and vehicles.
- Pest, animal and bird control without use of netting or mesh fences, covering a wide range of species: goannas, snakes, rabbits, hares, wombats, foxes, dingoes, wild dogs, cats, possums, flightless birds, swans, pigs, wallabies & kangaroos, goats, camels, wild horses, deer and donkeys.
- Tree protection requires only one wire, at 40-50cm (knee height). Stock introduced to a paddock which already has other stock habituated to power wires, quickly adjust. Those that do step over are easily returned over the low wire.
Back to Contents
Cattle & sheep
Effective electric fencing for cattle, calves, sheep and lambs consist of:
- 2 wires hand-tight at 53 and 23cm high; both wires charged at 4000 volts or more coupled at both ends.
- low leverage forces on posts are crucial; allow the economy of single hand-driveable 1.85m long unstayed end strain posts of 100-125mm diameter and 1.5m or shorter line posts.
- a 3rd wire close to the ground will help close off unevenness in the lower spacing.
Points to note:
- >Extra costs of wire are lower than those of altering the ground profile which may result in erosion or undesirable plant growth.
- Wires must run freely past their fastenings or insulators to allow even tensioning. Tuck straining can be done at several positions along the length of the strain, using permanent on-wire strainers or 'loop crimp and pin' joins in the wires, and should be located about 1m from a post to avoid the risk of wires catching together.
- Rigid posts with more facial area than typical fibreglass rod posts are needed on contours and freequently angled and dipping fence lines.
- Wood posts can be drilled as required for hair pins or wire fastenings. Fastening is provided by one legged or #J# staples or by pinning wires between pairs of staples. This allows wires to be lifted or lowered for stock or machinery movement.
- The use of 2-ire designs in intensive grazing of high rainfall and irrigated pastures and crop residues are an extension of widespread experience with 5, 4, 3 wire designs. Taller 6 wire fences, 1.2m high are typical for internal laneways and when fencing goats.
- On smooth terrain or on ground that can be economically 'stepped' or smoothed, wire suports such as posts, tree trunks, stumps, or high maintaining devices (HMDs), spaced at 30 to 50 paces or more are used.
- Laneway and hodling paddock fences and fences for weaning calves are more substantially wired and supported than subdivisional fences.
- The low cost and usefulness of long span-electric fencing is further highlighted by the flexibility of adequately tensioned small diameter smooth wires, free to run through all line and angle posts and HMDs and past gully and shoulder posts.
Such long spans can be readily:
- propped up with portable folding props of self insulating hardwood or elevated with tilts pivoting on posts for quick passage of stock under the wires or reduced pressure from flood debris. [I have known stock to refuse to go under or over a wire, for fear of an electric shock.]
- held down on the gorund for the passage of sheep and vehicles
- ridden over by motor bikes and short wheelbase vehicles which allow the wires to be pushed down by the foot or with a stick.
- driven over by multiwheeled vehicles and trailers fitted with front and underside wire deflectors, or driven over at points where pivoting 'drive-over' devices are fitted.
Back to Contents
Stock in general
Stock in general:
- adult cattle: single wire 750mm above ground
- sows: single wire at 375mm
- piglets: a second wire at 250mm
- sheep: 2 wires at 375 and 825mm. Wires must be kept taut so that when the animal pushes or rushes the fence, the wire passes through the hair to the skin
- rats: in a barn run 2 wires, one earthed, one live, 50mm apart, along the rafters at wall plate level; this can often clear rats from a barn overnight.
Vegetation under the wire must be kept clear of the wire to prevent short-circuiting. This is usually done by spraying with a herbicide such as glycophosphate.
Back to Contents
Fire & flood damage
Fire and flood damage to electric fences can be limited with:
- widely spaced posts using HMDs
- few wires and no barbs, and clearance above ground to allow grazing down of plant growth around posts and under and beyond the fence
- readily flexing and fluttering wires to help the passage of light water borne debris and wind blown grass, weeds and stubble
- no gate panels and attendant posts to collect debris and fuel.
- long span fences across wide flood plains are lifted on the approach of floods
- buoyant fences across creeks prone to flooding, contain stock and vermin, but allow floodwater and light debris to pass
- removable sections are used over creek beds, below the main fence wires, to anticipate heavy debris
- low cost expendable fencing can be used along main floodways where regualr debris damage occurs
- designs with wires mounted on slideable adjusted insulated mountings on posts provide for chanes in ground surface in the event of floods, sand or soil drifts and subsidence or land slips
Back to Contents
Disadvantages of electric fencing
Higher fences with more wires and vertical binders are needed in the rangelands, in extensive land use and goat control.
Powered wires carry the risk of arcing causing fires in Australia's hot dry vegetation. While rare, growth suppression along fence lines and turning off energisers during period of high fire danger are necessary. However, once stock are habituated to power lines, they will continue to avoid them when power is switched off.
Back to Contents